Q2A
Driving quality - Q2A tailored application drive
- Open/closed loop speed or torque control
- Embedded functional safety (STO SIL3)
- Built-in C3 class EMC filter
- Conform to EN 60721-3-3, 3S2 and 3C2
- Built-in braking transistor (up to 90 kW)
- Quick and easy setup with intuitive keypad and navigation
- Micro SD for data storage
- Real-Time Clock
- 24 VDC power supply input for control board
- Communication options: EtherCAT, EtherNet/IP, PROFINET, POWERLINK
- Mobile Device connectivity (via USB or optional Bluetooth)
- Regenerative solutions as option
- CE, UL, cUL, EAC, RoHS
Product discontinuation: December 2024 is applicable ONLY for EUROPE. Please download this discontinuation notice for further information.
Specifications & ordering info
Product | Drive control method | Drive supply voltage | Max. motor output at constant torque | Max. motor output at variable torque | Built in EMC filter | Degree of protection (IP) | Finless type | Compatible motor type | Regenerative solutions | Communication port(s) | Communication option(s) | Description | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 0.55 kW | 0.75 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 3.5 A / 0.75 kW, HD: 3.2 A / 0.55 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 0.75 kW | 1.1 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 6 A / 1.1 kW, HD: 5 A / 0.75 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 1.5 kW | 2.2 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 9.6 A / 2.2 kW, HD: 8 A / 1.5 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 2.2 kW | 3.0 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 12.2 A / 3.0 kW, HD: 11 A / 2.2 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 4.0 kW | 5.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 21 A / 5.5 kW, HD: 17.5 A / 4.0 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 5.5 kW | 7.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 30 A / 7.5 kW, HD: 25 A / 5.5 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 7.5 kW | 11 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 42 A / 11 kW, HD: 33 A / 7.5 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 11 kW | 15 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 56 A / 15 kW, HD: 47 A / 11 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 15 kW | 18.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 70 A / 18.5 kW, HD: 60 A / 15 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 18.5 kW | 22 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 82 A / 22 kW, HD: 75 A / 18.5 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 22 kW | 30 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 110 A / 30 kW, HD: 88 A / 22 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 30 kW | 37 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 138 A / 37 kW, HD: 115 A / 30 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 37 kW | 45 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 169 A / 45 kW, HD: 145 A / 37 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 45 kW | 55 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 211 A / 55 kW, HD: 180 A / 45 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 230 V three phase | 90 kW | 110 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 200 V, ND: 360 A / 110 kW, HD: 346 A / 90 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 0.55 kW | 0.75 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 400 V, ND: 2.1 A / 0.75 kW, HD: 1.8 A / 0.55 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 0.75 kW | 1.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 400 V, ND: 4.1 A / 1.50 kW, HD: 3.4 A / 0.75 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 1.5 kW | 2.2 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 400 V, ND: 5.4 A / 2.20 kW, HD: 4.8 A / 1.50 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 2.2 kW | 3.0 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 400 V, ND: 7.1 A / 3.00 kW, HD: 5.5 A / 2.20 kW, IP20, max. output freq. 590 Hz |
|
|
Closed loop V/f, Closed loop vector, Open loop V/f, Open loop vector | 400 V three phase | 5.5 kW | 7.5 kW | Yes | IP20 | No | Induction or asynchronous motor, Permanent magnet motor, Synchronous reluctance motor | As inverter option | MODBUS Slave, Serial RS-485, USB | Bluetooth, CANopen, DeviceNet Slave, EtherCAT Slave, EtherNet/IP, POWERLINK, PROFIBUS DP Slave, PROFINET Slave | Inverter Q2A, 400 V, ND: 17.5 A / 7.5 kW, HD: 14.8 A / 5.5 kW, IP20, max. output freq. 590 Hz |
|
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Contact me Q2A
Thank you for submitting your request. We will come back to you as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadQuotation for Q2A
By completing this form you can request a quotation. Your personal details will be handled confidentially.
Thank you for requesting a quotation. We will provide you with the required information as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadFeatures
Improved motor performance
- Q2A series is able to control different motor types in open and closed loops.
- Up to 590 Hz as standard.
- Zero speed control without encoder.
- Tuning-less with EZ vector.
- Advanced motor control for IM, PM & SynRM motors.
Cost effective network integration
Up to 5 Q2A with a single communication option card.
PC configuration tools: Q2edit and Q2dev
Optimize your engineering time. Graphic Development Environment provides faster application customization. Graphical setup: Q2 edit software tool provides parameter setting and monitoring for computers and smart devices.
Program >> Deploy >> Go
Q2A drive series can be programmed without any power supply connected. Simply plug into one of your PC’s USB ports, start programming and enjoy the ease of commissioning.
Q2app
Q2app
- Q2app allow you to connect to your Q2 series drives via Bluetooth or mini USB connection (only for Android devices).
- Q2A & Q2V inverters are supported.
- Drive status screen shows main indicators like motor speed, frequency reference, output frequency, output current, drive status, digital inputs and outputs status for a quick drive diagnosis.
- Any parameter can be changed and thanks to chart diagram visualization you can trace any parameter or monitor evolution over time.
- Hardware information can be checked as inverter family, model, serial number and firmware version, even if the ID label is not accessible.
Apple store Q2app
Scan to go directly to the Apple store to download the Q2app. Compatible with iPhone, iPad and iPod Touch.
Google Play store Q2app
Scan to go directly to the Google Play store to download the Q2app. Compatible with Android devices.