NX7
Sysmac controller – NX7 series
The NX7 series is a high performance CPU that includes two synchronized motion cores controlling up to 256 axes.
- OPC UA server built-in as standard feature, variable structures are supported
- Fastest cycle time: 125 µs
- Number of axes: 256, 128
- Two synchronized motion cores
- Functions: Logic sequence, Database connection, AI, Motion and OPC UA
- Database direct connection: SQL client for server Microsoft SQL, Oracle, IBM DB2, MySQL, Firebird, PostgreSQL
- Database direct connection in V2.0 is expanded with stored procedure calls and secure communications functionality
- AI Functionality: AI engine included in the controller enables real time utilisation of machine learning model
- AI Predictive Maintenance Library enables non-stop equipment
- Multi-tasking
- Built-in EtherCAT and two EtherNet/IP (1 Gbps) ports
Specifications & ordering info
Ordering information
Power supply units
Symbol | Description | Output capacity | RUN output | Order code |
---|---|---|---|---|
Total | ||||
100 to 240 VAC power supply unit for NX7 CPU | 90 W | Supported | NX-PA9001 | |
24 VDC power supply unit for NX7 CPU | 70 W | NX-PD7001 |
NX7 series CPU units
Symbol | CPU | Program capacity | Variables capacity | Power consumption | Functionalities | Number of axes | Order code | |||
---|---|---|---|---|---|---|---|---|---|---|
Sequence | Motion | DB connection | AI | |||||||
NX701 | 80 MB | 4 MB: Retained 256 MB: Not retained |
40 W | 256 | NX701-1720 | |||||
128 | NX701-1620 | |||||||||
256 | NX701-Z700 | |||||||||
128 | NX701-Z600 | |||||||||
256 | NX701-1700 | |||||||||
128 | NX701-1600 |
The end cover unit NX-END01 is included with the CPU unit.
EtherCAT junction slave
Symbol | Appearance | Name | No. of ports | Power supply voltage | Current consumption (A) | Dimensions (W x D x H) | Weight | Order code |
---|---|---|---|---|---|---|---|---|
EtherCAT junction slave | 3 | 20.4 to 28.8VDC (24 VDC –15 to 20%) |
0.08 | 25 mm × 78 mm × 90 mm | 165 g | GX-JC03 | ||
6 | 0.17 | 48 mm × 78 mm × 90 mm | 220 g | GX-JC06 |
- Please do not connect EtherCAT junction slave with OMRON position control unit, Model CJ1W-NC_81/_82.
- EtherCAT junction slave cannot be used for Ethernet/IP and Ethernet.
Industrial switching hub
Symbol | Appearance | Specifications | Accessories | Current consumption (A) | Order code | ||
---|---|---|---|---|---|---|---|
Functions | No. of ports | Failure detection | |||||
Quality of Service (QoS): EtherNet/IP control data priority. Failure detection: Broadcast storm and LSI error detection 10/100 BASE-TX, Auto-Negotiation |
3 | No | Power supply connector | 0.22 | W4S1-03B | ||
5 | No | W4S1-05B | |||||
5 | Yes | Power supply connector and connector for informing error | W4S1-05C |
Recommended EtherCAT and EtherNet/IP communication cables
Symbol | Item | Manufacturer | Color | Cable length (m) | Order code | ||
---|---|---|---|---|---|---|---|
EtherCAT cable | Cat 5e, AWG22, 2-pair cableM12/Smartclick connectorsImproved shield for EtherCAT communications | Standard typeCable with connectors on both ends(M12 straight/M12 straight) | OMRON | Black | 0.5 | XS5W-T421-BM2-SS | |
1 | XS5W-T421-CM2-SS | ||||||
2 | XS5W-T421-DM2-SS | ||||||
3 | XS5W-T421-EM2-SS | ||||||
5 | XS5W-T421-GM2-SS | ||||||
10 | XS5W-T421-JM2-SS | ||||||
Rugged typeCable with connectors on both ends(M12 straight/RJ45) | Black | 0.5 | XS5W-T421-BMCSS | ||||
1 | XS5W-T421-CMC-SS | ||||||
2 | XS5W-T421-DMC-SS | ||||||
3 | XS5W-T421-EMC-SS | ||||||
5 | XS5W-T421-GMC-SS | ||||||
10 | XS5W-T421-JMC-SS | ||||||
Ethernet/EtherCAT patch cable | Cat 6a, AWG27, 4-pair cableCable sheath
material: LSZH
2
,The lineup features low smoke
zero halogen cables for in-cabinet use and PUR cables for out-of-cabinet
use.
2
This cable is available in yellow, green
and blue colors. |
Standard typeCable with connectors on both ends (RJ45/RJ45) | Yellow | 0.2 | XS6W-6LSZH8SS20CM-Y | ||
0.3 | XS6W-6LSZH8SS30CM-Y | ||||||
0.5 | XS6W-6LSZH8SS50CM-Y | ||||||
1 | XS6W-6LSZH8SS100CM-Y | ||||||
1.5 | XS6W-6LSZH8SS150CM-Y | ||||||
2 | XS6W-6LSZH8SS200CM-Y | ||||||
3 | XS6W-6LSZH8SS300CM-Y | ||||||
5 | XS6W-6LSZH8SS500CM-Y | ||||||
7.5 | XS6W-6LSZH8SS750CM-Y | ||||||
10 | XS6W-6LSZH8SS1000CM-Y | ||||||
15 | XS6W-6LSZH8SS1500CM-Y | ||||||
20 | XS6W-6LSZH8SS2000CM-Y | ||||||
Green | 0.2 | XS6W-6LSZH8SS20CM-G | |||||
0.3 | XS6W-6LSZH8SS30CM-G | ||||||
0.5 | XS6W-6LSZH8SS50CM-G | ||||||
1 | XS6W-6LSZH8SS100CM-G | ||||||
1.5 | XS6W-6LSZH8SS150CM-G | ||||||
2 | XS6W-6LSZH8SS200CM-G | ||||||
3 | XS6W-6LSZH8SS300CM-G | ||||||
5 | XS6W-6LSZH8SS500CM-G | ||||||
7.5 | XS6W-6LSZH8SS750CM-G | ||||||
10 | XS6W-6LSZH8SS1000CM-G | ||||||
15 | XS6W-6LSZH8SS1500CM-G | ||||||
20 | XS6W-6LSZH8SS2000CM-G | ||||||
Ethernet/EtherCAT patch cable | Cat 5e, AWG26, 4-pair cableCable sheath
material: PUR
2
The lineup features low smoke
zero halogen cables for in-cabinet use and PUR cables for out-of-cabinet
use. |
Standard typeCable with connectors on both ends (RJ45/RJ45) | OMRON | Green | 0.5 | XS6W-5PUR8SS50CM-G | |
1 | XS6W-5PUR8SS100CM-G | ||||||
1.5 | XS6W-5PUR8SS150CM-G | ||||||
2 | XS6W-5PUR8SS200CM-G | ||||||
3 | XS6W-5PUR8SS300CM-G | ||||||
5 | XS6W-5PUR8SS500CM-G | ||||||
7.5 | XS6W-5PUR8SS750CM-G | ||||||
10 | XS6W-5PUR8SS1000CM-G | ||||||
15 | XS6W-5PUR8SS1500CM-G | ||||||
20 | XS6W-5PUR8SS2000CM-G | ||||||
Cat 5e, AWG22, 2-pair cable | Rugged typeCable with connectors on both ends (RJ45/RJ45) | Grey | 0.3 | XS5W-T421-AMD-K | |||
0.5 | XS5W-T421-BMD-K | ||||||
1 | XS5W-T421-CMD-K | ||||||
2 | XS5W-T421-DMD-K | ||||||
3 | XS5W-T421-EMD-K | ||||||
5 | XS5W-T421-GMD-K | ||||||
10 | XS5W-T421-JMD-K | ||||||
15 | XS5W-T421-KMD-K | ||||||
Rugged typeCable with connectors on both ends (M12 straight/RJ45) | Grey | 0.3 | XS5W-T421-AMC-K | ||||
0.5 | XS5W-T421-BMC-K | ||||||
1 | XS5W-T421-CMC-K | ||||||
2 | XS5W-T421-DMC-K | ||||||
3 | XS5W-T421-EMC-K | ||||||
5 | XS5W-T421-GMC-K | ||||||
10 | XS5W-T421-JMC-K | ||||||
15 | XS5W-T421-KMC-K | ||||||
Cat 5e, AWG22, 2-pair cable | Rugged typeCable with connectors on both ends (M12 L right angle/RJ45) | Grey | 0.3 | XS5W-T422-AMC-K | |||
0.5 | XS5W-T422-BMC-K | ||||||
1 | XS5W-T422-CMC-K | ||||||
2 | XS5W-T422-DMC-K | ||||||
3 | XS5W-T422-EMC-K | ||||||
5 | XS5W-T422-GMC-K | ||||||
10 | XS5W-T422-JMC-K | ||||||
15 | XS5W-T422-KMC-K | ||||||
Ethernet installation cable | Cat 5, SF/UTP, 4 × 2 × AWG 24/1 (solid core), Polyurethane (PUR) | Weidmüller | Green | 100 | WM IE-5IC4x2xAWG24/1-PUR | ||
Cat 5, SF/UTP, 4 × 2 × AWG 26/7 (stranded core), Polyurethane (PUR) | Green | 100 | WM IE-5IC4x2xAWG26/7-PUR | ||||
Connectors | RJ45 metallic connectorFor AWG22 to AWG26 | – | – | WM IE-T0-RJ45-FH-BK | |||
RJ45 plastic connectorFor AWG22 to AWG24 | OMRON | – | – | XS6G-T421-1 | |||
RJ45 socket | DIN-rail mount socket to terminate installation cable in the -cabinet | Weidmüller | – | – | WM IE-T0-RJ45-FJ-B |
Please be careful while cable processing, for EtherCAT, connectors on both ends should be shield connected and for EtherNet/IP, connectors on only one end should be shield connected.
WE70 FA wireless LAN units
Appearance | Name | Area | Type | Order code |
---|---|---|---|---|
WE70 FA wireless LAN units | Europe | Access point (Master) | WE70-AP-EU | |
Client (Slave) | WE70-CL-EU | |||
Directional magnetic-base antenna | 1 set with two antennas, 2.4 GHz/5 GHz Dual-band compatible | WE70-AT001H | ||
DIN rail mounting bracket | For TH35 7.5 | WT30-FT001 | ||
For TH35 15 | WT30-FT002 | |||
Antenna extension cable | 5 m | WE70-CA5M |
Special versions are available for USA, Canada, China and Japan.
Accessories
Appearance | Specifications | Order code | |
---|---|---|---|
SD memory card | 2 GB | HMC-SD291 | |
4 GB | HMC-SD491 | ||
DIN track | Length: 0.5 m; height: 7.3 mm | PFP-50N | |
Length: 1 m; height: 7.3 mm | PFP-100N | ||
Length: 1 m; height: 16 mm | PFP-100N2 | ||
Battery for NX7/NJ CPU unit (The battery is included with the CPU unit) | CJ1W-BAT01 | ||
End cover (The end cover is included with the CPU unit. Necessary to be connected to the right end of the CPU rack) | NX-END01 | ||
Fan unit (The fan unit is included with the CPU unit) | NX-FAN01 |
Computer software
Specifications | Order code | ||
---|---|---|---|
Sysmac Studio
2
For the NX701-Z
CPU units (with Artificial Intelligence), Sysmac Studio version
1.25 or higher is needed. |
SYSMAC-SE2___
2
Refer
to the Sysmac Studio datasheet (https://industrial.omron.eu/en/products/sysmac-studio)
for detailed information or contact your OMRON representative. |
||
AI Controller Software | Software that provides an operation interface for AI programming | DVD | SYSMAC-AICSTE00D |
1 license | SYSMAC-AICSTE01L |
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Contact me NX7
Thank you for submitting your request. We will come back to you as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadQuotation for NX7
By completing this form you can request a quotation. Your personal details will be handled confidentially.
Thank you for requesting a quotation. We will provide you with the required information as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadDirect access to SQL Database
Stored procedure
What is stored procedure?
Stored procedure is one of the database functions. A group of SQL statements is stored in a database, enabling complex processing to be executed with one call. The Stored Procedure Call function to call stored procedure in a database from the controller has been added to version 2.0.
Secure connection between FA and IT
Authentication based on server certificates and encrypted communications ensure safe connection between a database server and the CPU unit.*1
5 times faster data collection than the previous method
Batch Insert can store various types of data for a long time, just like an event data recorder. This allows you to identify the causes of line stoppages by analyzing data collected every scan.*1*2
Automatic generation of tables from structures and vice versa
A database table can be automatically generated from a structure, and a structure can be automatically generated from a database table. Mapping time can be reduced.*1
1. Available in NX701-1□20 and NX102-□□20. Will be available in NJ□01-□□20 soon.
2. Compared with when multiple insertions are performed.
3. A stored procedure is required to delete tables.
Software
AI Controller Software
The AI Predictive Maintenance Library, a collection of software components, calculates optimal future values to judge behaviour from data of operating mechanism.