ZX1
- CAD Library
- EPLAN parts data
- ZX1 Smart Laser Sensor with Built-in Amplifier Datasheet
Thank you for downloading the ZX1 Smart Laser Sensor with Built-in Amplifier Datasheet
Download againDid you know that 4 out of 5 distributors buy this product in a bundle?
There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

Highest performance for optimized productivity
For high precision laser CMOS sensor with separate amplifier see E3NC-S.
- Stable measurement for objects with any surface
- Best in class performance for accuracy and speed
- Compact size for quick mounting
- Increased measurement range
- Simple configuration by one-button, Smart Tuning
- Reliable measurement in harsh environments
- Integrated display
Ordering information
Sensors
![]() |
||||||||
![]() |
||||||||
Accessories (sold separately)
Extension cables for pre-wired connector models
An Extension cable is not provided with the sensor. Order an extension cable separately.
Specifications
Visible-light semiconductor laser |
||||||
(Defined at the measurement center distance) 2 |
||||||
Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 1 V max. (load current 10 mA or less), 2 V max. (load current of 10 to 100 mA)) |
||||||
Digital display (red), output indicator (OUT1, OUT2) (orange), zero reset indicator (orange), menu indicator (orange), laser ON indicator (green), and smart tuning indicator (blue) |
||||||
Temperature characteristic 3 |
||||||
Linearity 4 |
||||||
Resolution 5 |
||||||
Operating: -10 to 55°C, Storage: -15 to 70°C (with no icing or condensation) |
||||||
10 to 55 Hz, 1.5-mm double amplitude, 2 hours each in X, Y, and Z directions |
||||||
Degree of protection 6 |
||||||
Case and cover: PBT (polybutylene terephthalate), Optical window: Glass, Cable: PVC, Mounting hole part: SUS303 |
||||||
Note: False detection outside the measurement range can occur in the case of an object with high reflectance.
1. Classified as Class 2 by EN60825-1 criteria in accordance with the FDA standard previsions of Laser Notice No. 50. Notification to CDRH planned. (Center for Devices and Radiological Health)
2.
Spot diameter: Defined as 1/e² (13.5%) of the central intensity at the measurement center distance.
False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object.
Accurate measurements may not be possible for workpieces that are smaller than the spot diameter.
3. Temperature characteristic: Value for the case the space between the sensor and Omron’s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)
4. Linearity: Indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’s standard target object (white ceramic) at a temperature of 25°C. Linearity and measured value may vary depending on target object.
5.
Resolution: Defined in Standard Mode for Omron’s standard target object (white ceramic) after executing Smart Tuning.
The resolution indicates the repetition accuracy for a still workpiece. Not an indication of the distance accuracy.
Resolution performance may not be satisfied in a strong electromagnetic field.
1. Classified as Class 2 by EN60825-1 criteria in accordance with the FDA standard previsions of Laser Notice No. 50. Notification to CDRH planned. (Center for Devices and Radiological Health)
2.
Spot diameter: Defined as 1/e² (13.5%) of the central intensity at the measurement center distance.
False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object.
Accurate measurements may not be possible for workpieces that are smaller than the spot diameter.
3. Temperature characteristic: Value for the case the space between the sensor and Omron’s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)
4. Linearity: Indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’s standard target object (white ceramic) at a temperature of 25°C. Linearity and measured value may vary depending on target object.
5.
Resolution: Defined in Standard Mode for Omron’s standard target object (white ceramic) after executing Smart Tuning.
The resolution indicates the repetition accuracy for a still workpiece. Not an indication of the distance accuracy.
Resolution performance may not be satisfied in a strong electromagnetic field.
Brochures
Show all brochuresDatasheets
Show all datasheetsManuals
Show all manualsSubscribe to product updates
Newsletters about product innovations, solutions and services, directly in your inbox.
Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadTraining courses
Get the training from our best engineers. Beginner to advanced level.
View training courses